MAINTENANCE
HPR260 Manual Gas Instruction Manual 5-41
4
Pilot arc current levels
The pilot arc current level will change depending on the chosen process and arc current level. See table below.
Pilot arc current
Plasma gas 30-amps 45-amps 50-amps 80-amps 130-amps 200-amps 260-amps
O
2
25 30 30 30 30 40 40
N
2
25 30 30 30 35 40 40
H35 25 30 30 30 35 40 40
F5 25 30 30 30 35 40 40
Air 25 30 30 30 35 40 40
Transfer current
Plasma gas 30-amps 45-amps 50-amps 80-amps 130-amps 200-amps 260-amps
O
2
10 10 10 10 15 20 20
N
2
10 10 10 10 15 20 20
H35 10 10 10 10 15 20 20
F5 10 10 10 10 15 20 20
Air 10 10 10 10 15 20 20