INSTALLATION
3-26 HPR260 Manual Gas Instruction Manual
Examples of output circuits
1. Logic interface, active-high
2. Logic interface, active-low
3. Relay interface
4. Do not use this configuration. Warranty will be void.
High-impedance (10mA)
10K
(optional)
CNC/PLC
5VDC-24VDC
C
HPR
E
+
HPR
C
E
+
5VDC-24VDC
High-impedance (10mA)
CNC/PLC
10K
(optional)
CNC/PLC
CNC +24V
+24VDC
CNC +24V
HPR
C
E
+
Power
ground
External relay
24VDC low-power coil
10mA or 2400ohm
High-current
contact closure
inputs (AC or DC)
°t
Any voltage
VOIDS
WARRANTY
HPR
Install a
Jumper
108056
J304
C
E
+

Table of Contents