MAINTENANCE
5-52 HPR260 Manual Gas Instruction Manual
Preventive Maintenance Master Schedule
Daily:
Verify proper inlet gas pressure.
Verify proper gas flow settings. – Mandatory at every consumable change.
Inspect torch and replace consumables as needed.
Weekly:
Week Jan Feb March April May June July Aug Sept Oct Nov Dec
1
2
3
4
5
Semi-Annually:
Year 1
st
Service 2
nd
Service
Clean power supply with dry, oil free compressed air, or a vacuum cleaner.
Verify cooling fans are working properly.
Clean torch threads and current ring.
Verify proper coolant level.
Annually:
Year
Replace service parts per the Service Part Replacement Schedule.
Replace service parts per the Service Part Replacement Schedule.