Changed Page Description
IM804940 Rev 0 to 1
8/05/05
3.29
Updated art for step number 5 to show the new pilot arc connector. Added text to step number 5 "
Tighten by hand only".
3.33
Corrected recommended cable size for 200/208V, rated for 90 degrees C. It was (2 AWG) and is
now (2/0 AWG). Corrected recommended cable size for 240V, rated for 60 and 90 degrees C. 60
degrees C was (4 AWG) and is now (4/0 AWG). 90 degrees C was (1 AWG) and is now (1/0 AWG)
4.10-4.30 All marking cut charts updated.
5.7-7.12
(General)
Added Metric units where needed in the troubleshooting tables.
5.11
The description for error code number 102 was changed from "Chopper current signal is active on
power-up" to "No current or over-current detected during chopper test at power-up".
5.19 Removed "and strainer" from heading. There is no strainer in the cooling system.
5.39 and 5.40 Corrected the numbering of the checklist. It used to go from number 4 to number 6.
6.2
Added /208 to the description for part number 078187.
6.5
Added /208 to the description for part number 129786.