HyPrecision 50S/60S/75S Operator Manual 808690 57
4 Operation
Operation
Pump settings screen
The pump settings screen provides access to the system settings menu, the pump set up (configuration), and to
the pressure adjustment screen.
System settings allow the user to enable and disable pump options. If the system has a proportional control
valve, the settings for proportional ramping are found here.
Idle Shutdown
When enabled, the pump turns off after a specified time (Idle Time) without the
intensifier stroking.
Idle Cooling
When enabled, the pump goes into cooling mode after a specified time (Idle Time)
without the intensifier stroking.
Idle Time (minutes)
Set the number of minutes for Idle Shutdown and Idle Cooling.
Analog Pressure Input
Enable this when a remote 0 V to 10 V input is used to control the proportional valve.
Boost Fault Monitor
When enabled, fault monitoring alerts the operator to a boost pump fault.
Fan Fault Monitor
When enabled, fault monitoring alerts the operator to a fan motor fault.
This is for air-cooled systems.