EasyManuals Logo

Hypertherm powermax1250 User Manual

Hypertherm powermax1250
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Power supply
SPECIFICATIONS
1
2-2 powermax1250 Operator Manual
Rated open circuit voltage (U
0
) 300 VDC
OutputCharacteristic* Drooping
*Defined as a plot of output voltage
versus output current
Rated output current (I
2
) 25A – 80A
Hypertherm standard rated output 150 VDC
voltage (U
2
)
Duty cycle (X*) at 104°F (40°C) at U
1
– Volts AC rms X
rated conditions (U
1
, I
1
, U
2
, I
2
) 200-208 VAC 1PH 40%
230-240 VAC 1PH 50%
*X = T
on
/T
base
, 480 VAC 1PH 60%
T
on
= time, minutes 200-208 VAC 3PH 50%
T
base
= 10 minutes 230-240 VAC 3PH 60%
(See the data plate on the power supply for 380-400-415 VAC 3PH 60%
more information on duty cycle and for IEC 480 VAC 3PH 60%
ratings.) 600 VAC 3PH 60%
Operating temperature 14
o
to 104
o
F (-10
o
to 40
o
C)
Rated AC phases (PH) and line frequency (Hz) PH Hz
Standard model 1-3 50-60
CE model 3 50-60
Rated input voltage (U
1
), rated input U
1
– Volts AC rms I
1
-Amps rms I
1
eff
current (I
1
) and I
1
eff* at rated output 200-208 VAC 1PH 70 44
U
2
and I
2
– cutting only. 230-240 VAC 1PH 60 42
480 VAC 1PH 30 23
200-208 VAC 3PH 40 28
*I
1
eff = (I
1
) X used to determine 230-240 VAC 3PH 36 28
rating of power cord. 380-400-415 VAC 3PH 21 16
480 VAC 3PH 17 13
600 VAC 3PH 16.5 13
Power factor U
1
– Volts AC rms Harmonic power factor Displacement
power factor
200-208 VAC 1PH 0.99 0.99
230-240 VAC 1PH 0.99 0.99
480 VAC 1PH 0.91 0.99
200-208 VAC 3PH 0.94 0.99
230-240 VAC 3PH 0.94 0.99
380-400-415 VAC 3PH 0.94 0.99
480 VAC 3PH 0.94 0.99
600 VAC 3PH 0.80 0.99
R
sce
– short circuit ratio—CE model only U
1
– Volts AC rms, 3PH R
sce
400 VAC 228
230 VAC 163
This equipment conforms to IEC 61000-3-12,
provided that R
sce min
= 228 at 400VAC 3PH and
163 at 230 VAC 3PH.
IP code—degree of protection IP23CS*
provided by enclosure IP – “International Protection”
2 – No ingress foreign objects
>
=12.5mm (0.5 in)
3 – No harmful ingress spraying water
C – AC line circuits protected against ingress of
tool
>
=2.5 mm dia. x 100 mm long
(0.1 inch x 4.0 inch)
S – fan stationary during water test
*
WARNING: DO NOT OPERATE IN RAIN
Toppling, tilting (with or without wheel kit) Up to 15
o
incline
.
Gas type Air Nitrogen
Gas quality Clean, moisture-free, oil-free
Gas inlet pressure and flow See
Section 3, Setup

Table of Contents

Other manuals for Hypertherm powermax1250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm powermax1250 and is the answer not in the manual?

Hypertherm powermax1250 Specifications

General IconGeneral
BrandHypertherm
Modelpowermax1250
CategoryWelding System
LanguageEnglish

Related product manuals