EasyManua.ls Logo

Hypertherm powermax1250 - Adjust the Gas Pressure and Current Setting

Hypertherm powermax1250
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION
0
powermax1250 Operator Manual 4-9
Adjust the gas pressure and current setting
AMPS
60
40
80
25
Set the current knob to gas test.
Pull the regulator knob to unlock.
6.0
BAR
5.04.0
PSI
80
7050 60
AMPS
60
40
80
25
Set the pressure:
Cutting 70–75 psig (4.8–5.2 bar)
Gouging 50–60 psig (3.4–4.1 bar)
Push the regulator knob to lock.
Turn the current knob away from gas test to
stop the gas flow (25 amps minimum).
1
2
3
4
5

Table of Contents