3-8
SETUP
Operator Manual
Three-Phase - CE
Conductor Color
Ground Green/Yellow
L3 (W) Black
L2 (V) Blue
L1 (U) Brown
Note: See also EMC
Compatibility and
Mains
Supply
on page i for further
power (supply) cable
shielding recommendations
for CE compliance.
TB1
Green/
Yellow
V
Blue
U
Brown
W
Black
(Filter Board)
Figure 3-9
Three-Phase CE Power
POWER REQUIREMENTS
Line Voltage Disconnect Box
Use a line disconnect box for each power supply. This disconnect box allows the operator to turn the
power supply off quickly in an emergency situation. The switch should be located on a wall near the
power supply, and should be easily accessible to the operator. The interrupt level of the switch must be
equal to or exceed the continuous rating of the fuses. Use slow-blow fuses according to the power
requirements listed below.
Input Input Current Recommended
Voltage Phase @ 6.6 kw Output Slow-Blow Fuse Size
200 VAC 1 57 amps 70 amp
208 VAC 1 55 amps 70 amp
230 VAC 1 50 amps 70 amp
240 VAC 1 47 amps 60 amp
400 VAC 1 33 amps 40 amp
480 VAC 1 28 amps 35 amp
200 VAC 3 33 amps 40 amp
208 VAC 3 32 amps 40 amp
230 VAC 3 29 amps 35 amp
230 VAC (CE) 3 31 amps 40 amp
240 VAC 3 28 amps 35 amp
400 VAC 3 18 amps 25 amp
400 VAC (CE) 3 18 amps 25 amp
480 VAC 3 15 amps 20 amp
600 VAC 3 12 amps 20 amp

Table of Contents

Other manuals for Hypertherm powermax900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm powermax900 and is the answer not in the manual?

Hypertherm powermax900 Specifications

General IconGeneral
BrandHypertherm
Modelpowermax900
CategoryWelding System
LanguageEnglish

Related product manuals