LITHIUM SERIEII Electric Torque Tool Operations Manual
24
NOTE: The HYTORC Nut inner sleeve is tightened in the counter clockwise direction (let hand threads).
Power on the tool, select the desired torque using the up and down arrow buttons and set theastener type to
HYTORC Nut
Position the tool over the nut
Pull the trigger to apply torque until the tool stalls at the speciied torque
I a RELEASE ANGLE has been speciied continue holding the trigger and the tool will restart and then stall again
ater completing the RELEASE angle. Then the tool can be released rom the nut.
Release the trigger ater the tool has completed all speciied operations
The status light will turn amber during operation. I the operation is successul, the status light will turn green, i
unsuccessul the status light will turn red.
I the BEEPER is enabled the tool will provide an audible beep upon completion othe operations
Remove the tool driver rom the nut
Should torque be applied without a release angle the tool may lock onto the nut. I this happens set the tool to
loosen to ree the tool and repeat the tighten operation.