3.4 Fieldbus Type Address Map
111
(2) I/O Signal Allocation for each Axis
The I/O signals for each axis consists of 8 words for each I/O bit register.
The control signals and status signals are ON/OFF signals in units of bit.
For the target position and current position, 2-word (32-bit) binary data is available and
values from -999999 to +999999 (unit: 0.01mm) can be used. Negative numbers are to be
dealt with two’s complement.
Set the positioning width. The positioning width is expressed using 2-word (32 bits) binary
data. The figures from 0 to +999999 (Unit: 0.01mm) can be set in PLC.
The command speed is expressed using 1-word (16 bits) binary data. The figures from 1 to
+65535 (Unit: 1.0mm/sec or 0.1mm/sec) can be set in PLC. A change of the unit is to be
conducted on Gateway Parameter Setting Tool.
The Acceleration/Deceleration is expressed using 1-word (16 bits) binary data. The figures
from 1 to 300 (Unit: 0.01G) can be set in PLC.
The pressing current limit value is expressed using 1-word (16 bits) binary data. The figures
from 0 to 100% (0 to FF
H) can be set in PLC.
Set Value
Push-motion current-limiting value
7F
H
(127 in decimal system)
0
100%50%0%
FF
H
(255 in decimal system)
The command current is expressed using 2-word (32 bits) binary data (Unit: 1mA).
The current speed is expressed using 1-word (16 bits) binary data (Unit: 1.0mm/sec or
0.1mm/sec).
The unit is the one set in the command speed. A positive number is output when the
revolution of the driving motor is in CCW, while a negative number when CW. Negative
numbers are output with two’s complement.
For Rotary Type, a positive number is output when rotating clockwise.
The alarm code is expressed using 1-word (16 bits) binary data.
Caution: Set the position data in the range of the soft stroke (0 to effective stroke length)
of
the actuator.
Caution: Have the setting with values available in the range of for speed,
acceleration/deceleration and pressing current of the actuator. (Refer to the catalog
or instruction manual of the actuator.) Otherwise, it may cause an abnormal
condition of the servo or a malfunction of the actuator such as the alarm codes 0A3
“Position Command Information Data Error”, 0C0 “Excess Actual Speed”, 0C8
“Overcurrent”, 0CA “Overheated” or 0E0 “Overloaded”.