Operation Manual Seventh Edition
X-SEL Controlle
r
P/Q Type

Table of Contents

Other manuals for IAI X-SEL

Questions and Answers

  • J
    Justin ClineSep 23, 2025
    What does oPG error mean on IAI X-SEL?
    • J
      Joshua RasmussenSep 23, 2025
      The oPG error on the IAI Controller indicates that the safety gate is open. To resolve this, check the system connector wiring.
  • L
    Linda JohnstonAug 23, 2025
    Why does my IAI Controller show ACF error?
    • R
      Robert WoodAug 25, 2025
      The ACF error on your IAI Controller typically indicates a momentary power failure or a voltage drop. This can also occur if you are inputting 100V into a controller that requires 200V. To fix this, check the power source voltage. Note that if the last digit of your controller's model number is '-1,' it requires 100V, while '-2' indicates a 200V specification.
  • J
    Jennifer GlennAug 25, 2025
    What to do if IAI X-SEL Controller displays error d10?
    • H
      Heather MurrayAug 26, 2025
      If your IAI Controller displays error d10, it may be due to a damaged motor coil or a faulty power stage board. First, measure the relative resistance among phases U/V/W. If the resistance values differ, the coil is likely burned, and you should replace the motor. However, if the resistance values are nearly identical, the coil is likely fine, and you should replace the power stage board (where the motor power cable connects).
  • J
    Jessica RuizAug 27, 2025
    What to do if IAI X-SEL displays CA5 error?
    • C
      Christopher RobertsonAug 27, 2025
      If your IAI Controller displays the CA5 error, it indicates that the operation is mechanically disabled or the power stage board is faulty. First, check if the actuator mounting bolts are contacting inside the axes or if the slider attachment is contacting any surrounding mechanical parts. If there are no mechanical issues, replace the power stage board.
  • T
    Tiffany BakerAug 27, 2025
    How to fix d03 error on IAI Controller?
    • J
      Jonathan FischerAug 27, 2025
      The d03 error on your IAI Controller suggests that the encoder is faulty or has dust attached. Remove the motor cover and use cleaning air spray designed for OA equipment on the cord wheel. If the problem continues, you may need to replace or readjust the encoder.
  • K
    kevin03Sep 16, 2025
    What to do if IAI X-SEL shows d06 error?
    • M
      Michael EllisSep 16, 2025
      The d06 error on the IAI Controller indicates that the encoder cable is disconnected. To fix this, replace the encoder cable.
  • N
    Natasha SavageSep 13, 2025
    What does C9C error mean on IAI X-SEL?
    • M
      Michael KiddSep 13, 2025
      The C9C error on the IAI Controller suggests that the phase-Z position is defective or the reversing amount at home return is small. Check if any foreign object has entered the actuator and ensure the mounting bolts are not contacting the slider. As a potential fix, change axis-specific parameter No. 22 to “100.”
  • D
    davidbergerSep 14, 2025
    What does 807 error mean on IAI X-SEL?
    • J
      jason13Sep 14, 2025
      The 807 error on the IAI Controller indicates that the transistor on the power-supply board (where the power cable connects) is damaged. To resolve this, replace the board.
  • C
    Crystal JonesSep 5, 2025
    What to do if IAI X-SEL displays dSF error?
    • B
      Bobby HoffmanSep 5, 2025
      If your IAI Controller displays the 'dSF' error, it means the switch is set to the manual side when the teaching connector or another connector is not connected. To fix this, set the switch to the auto side when no connector is connected.
  • S
    schambersSep 3, 2025
    What does d19 error mean on IAI X-SEL?
    • S
      Samuel SimmonsSep 3, 2025
      The d19 error on your IAI Controller indicates that the encoder cable is disconnected. To resolve this, replace the encoder cable.