3.11 Gateway status LED
231
3.11 Gateway status LED
ALM RDY
MODE
EMG
T.ERR
C.ERR
{ : Illuminating, × : OFF, : Flashing
Name
Lamp
status
Color Description
{ Green Normal
{ Orange Alarm issued
ALM/RDY
× Control power supply OFF
{
Green AUTO mode being selected
MODE
× MANU mode being selected
{
Red Emergency-stop input
EMG
× Not an emergency stop
{
Orange
Communication error between
Gateway Ù driver board
T.ERR
× –
Not a communication error between
Gateway Ù driver board
{
Orange Field network communication error
C.ERR
× –
Not a field network communication
error