EasyManua.ls Logo

IAI MSCON - 3.10 Field network status LEDs

IAI MSCON
360 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.10 Field network status LEDs
227
3.10 Field network status LEDs
The communication status of the field network can be checked.
3.10.1 DeviceNet
NS
MS
3.10.2 CC-Link
ERR
RUN
{ : Illuminating, × : OFF, : Flashing
Name
Lamp
status
Color Description
{
Online (normally)
Green
Online (Even though the network
is established normally, it is not
identified as MSCON by the
master)
{
An error occurs.
Orange
No response returned from
another slave.
NS
(Illuminated
by turns)
Green /
Orange
In self-checking process.
{
Communication in normal
condition
Green
Parameter setting error
{
Hardware breakdown
Orange
Light malfunction
MS
(Illuminated
by turns)
Green /
Orange
In self-checking process.
Field
Network
Connector
Field
Network
Status
LED
{ : Illuminating, × : OFF, : Flashing
Name
Lamp
status
Color Description
{
An error occurs. (CRC error,
station No. setting error, baud
rate setting error)
Orange
Station number or baud rate
changed after the power-on
ERR
× –
Normal
RUN
{
Green
Communication in normal
condition
Field
Network
Connector
ME0306-2A

Table of Contents

Related product manuals