EasyManua.ls Logo

IAI MSCON - 4.3 Setting of Position Data

IAI MSCON
360 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Vibration Suppress Control Function
237
[4] Default vibration suppress No. (Parameter No.109)
When a position is written into a position table not registered yet, the value set to this
parameter is automatically entered in the “Vibration suppress No.” field. To change the
setting, edit the position table later.
0: Normal position control (default)
1: Use Anti-Vibration Control Parameter Set 1
2: Use Anti-Vibration Control Parameter Set 2
3: Use Anti-Vibration Control Parameter Set 3
[5] Stop method at servo OFF (Parameter No.110)
The table below shows the relationship between the values of Parameter No.110 and stop
commands.
4.3 Setting of Position Data
To make the anti-vibration control effective, set the parameter set number to be used in
Anti-Vibration Number Column in Position Data.
Note: The vibration suppress control function cannot be used in pressing operation.
No.
Position
[mm]
Velocity
[mm/s]
Accele-
ration
[G]
Decele-
ration
[G]
Pressing
[%]
Thresh-
old
[%]
Positioning
width
[mm]
Zone+
[mm]
Zone-
[mm]
Acceleration/
Deceleration
mode
Incre-
mental
Gain
set
Stop
mode
Vibration
suppress
No.
0
1 0.00 50.00 0.01 0.01 0 0 0.10 0.00 0.00 0 0 0 0 0
2 50.00 50.00 0.01 0.01 0 0 0.10 0.00 0.00 0 0 0 0 1
3 50.00 50.00 0.01 0.01 50 0 0.10 0.00 0.00 0 0 0 0 3
4
Stop Process
0 1
Stop Command
Vibration
suppress
control
Normal
positioning
control
Vibration
suppress
control
Normal
positioning
control
Pause
Anti-vibration
deceleration
stop
Normal
deceleration
and stop
Servo OFF
Emergency Stop
Error
(Operation-cancellation
level alarms)
Sudden stop by
emergency stop torque
Anti-vibration
deceleration
stop
Normal
deceleration
and stop
Error
(Cold start)
Sudden stop by emergency stop torque
Set natural frequency 1 (enabled)
Set natural frequency 3 (It cannot be in common
with Error: 0A2 Position Data Error Pressing
Operation.)
ME0306-2A