3.4 Fieldbus Type Address Map
135
9) Reading of Pressing Width
PLC Output (Address n is the input and output top address for MSCON Gateway Unit.)
Bit
Address
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
n+2
Demand
Command
[1041h]
0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1
n+3
Data 0
[Position No.]
128
64
32
16
8
4
2
1
n+4
Data 1
[0]
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
n+5
Data 2
[0]
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Reading of Pressing Width
n+6
Data 3
[Axis No.]
4
2
1
PLC Input (Address n is the input and output top address for MSCON Gateway Unit.)
Bit
Address
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
n+2
Response
Command
[1041h]
0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1
n+3
Data 0
[Position No.]
128
64
32
16
8
4
2
1
n+4
Data 1
[Pressing Width
(Lower word)]
n+5
Data 2
[Pressing Width
(Upper word)]
Reading of Pressing Width
n+6
Data 3
[Axis No.]
4
2
1
1 word=16 bit
1 word=16 bit