3.8 C ontrol and functions of Input and output signals of Remote I/O Mode
181
[Shortcut control of rotary actuator of multi-rotation specification]
(1) Set of shortcut selection
The shortcut selection can be made valid/invalid by Parameter No.80 “rotation axis shortcut
selection”. If the shortcut selection is made valid, the actuator can be moved only in a single
direction.
[Operation Examples]
Position No. Position
1 0
2 90
3 180
4 270
Enter position data assuming 1° =
1mm.
(Example) 1.2 is assumed as 1.2°.
For operation in the order of positions 12341, the actuator is moved differently whether
the shortcut selection is valid or invalid.
y When shortcut selection is invalid:
y When shortcut selection is valid:
Position No.1
Position No.2
Position No.3
Position No.4