[10] Dynamic brake (Parameter No.14)
No. Name Symbol Unit Input Range
Default factory
setting
14 Dynamic Brake FSTP -
0: Disabled
1: Enabled
1
This parameter defines whether the dynamic brake is enabled or disabled while the actuator is
at standstill.
Normally it need not be changed.
[11] Pause input disable selection (Parameter No.15)
No. Name Symbol Unit Input Range
Default factory
setting
15 Pause Input Disable Selection FPIO -
0: Disabled
1: Enabled
0
This parameter defines whether the pause input signal is disabled or enabled.
If a pause operation is not needed, set the parameter to “1” and an operation becomes
available without controlling the pause signal.
Set Value Description
0 Enabled (Use)
1 Disabled (Does not use)
[12] Home position check sensor input polarity (Parameter No.18)
No. Name Symbol Unit Input Range
Default factory
setting
18
Home Position Check Sensor
Input Polarity
AIOF - 0 to 2
In accordance
with actuator
The home sensor is an option.
Set Value Description
0
Standard specification
(sensor not used)
1 Input is a contact
2 Input is b contact
[13] Overrun sensor input polarity (Parameter No.19)
No. Name Symbol Unit Input Range
Default factory
setting
19 Overrun Sensor Input Polarity AIOF - 0 to 2
In accordance
with actuator
This parameter is set properly prior to the shipment according to the specification of the
actuator.
Set Value Description
0 Standard specification without sensor
1 Over travel detection sensor input is a contact
2 Over travel detection sensor input is b contact