Chapter 1 Specications Check
29
1.4.3 Specifications of PROFIBUS-DP Interface
Item Specification
Communication
Protocol
PROFIBUS-DP
Baud Rate Automatically follows the master
Communication
System
Hybrid System (Master-Slave System or Token Passing System)
Number of
Occupied Stations
Refer to 3.4.1 PLC Address Construction by each Operation Mode
Max. Total Network Length Baud Rate Cable Type
100m 12,000/6,000/3,000kbps
200m 1,500kbps
400m 500kbps
1000m 187.5kbps
Communication
Cable Length
1200m 9.6/19.2/93.75kbps
Type A Cable
Communications
Cable
STP cable AWG18
Connector
(Note1)
9 pin female D-sub Connector
Transmission Path
Format
Bus/Tree/Star
Note 1: Prepare the 9-pin male D-sub connector as the connector on the cable side.
1.4.4 Specifications of CompoNet Interface
Item Specification
Communication System CompoNet specialized protocol
Communication Type Remote I/O Communication
Baud Rate Automatically follows the master
Communication Cable Length Follows CompoNet Type
Slave Type Word Mixed Slave
Available Node Addresses for
Setting
0 to 63 (Setting conducted on controller parameter)
Number of Occupied Channels Refer to 3.4.1 PLC Address Construction by each Operation Mode
Communications cable
(Note1)
Round-type cable (JIS C3306, VCTF2 conductors)
Flat cable I (with no sheathed)
Flat cable II (sheathed)
Connector (Controller side) XW7D-PB4-R(manufactured by OMRON or equiv.)
Note1: Prepare a communication cable separately.
ME0306-2A