Chapter 6 Power-saving Function
POWER CON
PCON-CB/LC
165
[For Parameter No.39 = 0]
Operation of actuator
Positioning
operation
Automatic servo
OFF standby
Servo OFF
Positioning
operation
Servo Condition ON
ON OFF ON
Completed Position No.
Output (Current position
number output)
PM1 to ** =0
(PE** = OFF)
PM1 to ** = Output
(PE** = ON)
PM1 to ** = 0
(PE** = OFF)
PM1 to ** = 0
(PE** = OFF)
Positioning Completion
Signal PEND
OFF ON OFF OFF
Servo OFF Delay
Time
(Parameter No.36 to 38)
[For Parameter No.39 = 1]
Operation of actuator
Positioning
operation
Automatic servo
OFF standby
Servo OFF
Positioning
operation
Servo Condition ON
ON OFF ON
Completed Position No.
Output (Current position
number output)
PM1 to ** = 0
(PE** = OFF)
PM1 to ** = Output
(PE** = ON)
PM1 to ** = 0
Output
(PE** = ON)
PM1 to ** = 0
(PE** = OFF)
Positioning Completion
Signal PEND
OFF ON ON OFF
Servo OFF Delay
Time
(Parameter No.36 to 38)

Table of Contents

Other manuals for IAI PCON-CFB series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IAI PCON-CFB series and is the answer not in the manual?

IAI PCON-CFB series Specifications

General IconGeneral
BrandIAI
ModelPCON-CFB series
CategoryController
LanguageEnglish

Related product manuals