3. SCON-CA
179
z Fieldbus baud rate (No. 86: FBRS)
Specify the baud rate in parameter No. 86.
Set value Baud rate
0 (Factory setting) Auto negotiation (recommended)
1 10 Mbps, half-duplex
2 10 Mbps, full-duplex
3 100 Mbps, half-duplex
4 100 Mbps, full-duplex
Other than the above Baud rate setting error
z Network type (No.87 NTYP)
The network module type is set for the parameter No. 87. Do not change the default value.