v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, “Parts listing, Types 7871 and 1949,” on page 41 to determine which components are CRUs and
which components are FRUs.
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error Code Type Error Message Action
0x80010700 Warning System board (Inlet Temp)
temperature over/under
warning threshold. Reading: X,
Threshold: Y
1. Make sure that the room temperature is within
the operating specifications (see “Features and
specifications” on page 8).
2. Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3. Make sure that all of the fans on the BladeCenter
unit are running.
0x80010900 Error Expansion Module 1 (BPE3 12V
Sense) voltage under critical
threshold. with chassis Reading:
X, Threshold: Y
1. If the under voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events (see
“Error logs” on page 99).
2. View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3. If other modules or blades are logging the same
issue then check the power supply for the
BladeCenter unit.
4. If the error continues, replace the Blade PCI
Express I/O expansion unit. See “Removing an
optional expansion unit” on page 57 and
“Installing an optional expansion unit” on page
58.
0x80010900 Error Expansion Module 1 (BPE3
12VSB Sense) voltage over
critical threshold. Reading: X,
Threshold: Y
1. If the over voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events.
2. View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3. If other modules or blades are logging the same
issue then check the power supply for the
BladeCenter unit.
4. If the error continues, replace the Blade PCI
Express I/O expansion unit. See “Removing an
optional expansion unit” on page 57 and
“Installing an optional expansion unit” on page
58.
104 BladeCenter HS22V Type 7871 and 1949: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM BladeCenter HS22V 7871 and is the answer not in the manual?

IBM BladeCenter HS22V 7871 Specifications

General IconGeneral
BrandIBM
ModelBladeCenter HS22V 7871
CategoryServer
LanguageEnglish

Related product manuals