Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 50
Automatically notify Support: No
User response: Complete the following steps:
1. Remove the I/O expansion adapter in I/O expansion connector 3.
2. Try to power on the chassis.
v If the chassis successfully powers on, complete the following steps:
a. Check the ServerProven website to make sure that recently installed components are compatible with the
chassis.
b. Inspect the previously installed components for physical damage.
v If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the
I/O expansion adapter.
80070617-2c04ffff Sensor Mezz Exp 4 Fault has transitioned to non-recoverable.
Explanation: A problem was detected in the I/O expansion adapter in I/O expansion connector 4. The adapter is
unable to initialize.
May also be shown as 800706172c04ffff or 0x800706172c04ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 50
Automatically notify Support: No
User response: Complete the following steps:
1. Remove the I/O expansion adapter in I/O expansion connector 4.
2. Try to power on the chassis.
v If the chassis successfully powers on, complete the following steps:
a. Check the ServerProven website to make sure that recently installed components are compatible with the
chassis.
b. Inspect the previously installed components for physical damage.
v If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the
I/O expansion adapter.
8008001b-1f07ffff Device Periscope 1 has been removed from unit [PhysicalPackageElementName].
Explanation: The fabric connector for LAN On Motherboard (LOM) in location 1 is not present.
May also be shown as 8008001b1f07ffff or 0x8008001b1f07ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0537
SNMP Trap ID:
Automatically notify Support: No
80070617-2c04ffff 8008001b-1f07ffff
Chapter 6. Troubleshooting 127