User response: Informational message.
On a LOM model compute node, if you are utilizing LOM and it is not working ensure you have the necessary fabric
connector installed.
v To utilize the LOM:
have the LOM model compute node
have the corresponding fabric connector installed
v Information regarding the fabric connectors:
LOM 1 utilizes the fabric connector in location 1.
LOM 2 utilizes the fabric connector in location 2.
I/O expansion adaptor in I/O expansion slot 1 and the fabric connector in slot 1 utilize the same connector and
only one of the two can be installed at a time.
I/O expansion adaptor in I/O expansion slot 3 and the fabric connector in slot 2 utilize the same connector and
only one of the two can be installed at a time.
8008001b-1f08ffff Device Periscope 2 has been removed from unit [PhysicalPackageElementName].
Explanation: The fabric connector for LAN On Motherboard (LOM) in location 2 is not present.
May also be shown as 8008001b1f08ffff or 0x8008001b1f08ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0537
SNMP Trap ID:
Automatically notify Support: No
User response: Informational message.
On a LOM model compute node, if you are utilizing LOM and it is not working ensure you have the necessary fabric
connector installed.
v To utilize the LOM:
have the LOM model compute node
have the corresponding fabric connector installed
v Information regarding the fabric connectors:
LOM 1 utilizes the fabric connector in location 1.
LOM 2 utilizes the fabric connector in location 2.
I/O expansion adaptor in I/O expansion slot 1 and the fabric connector in slot 1 utilize the same connector and
only one of the two can be installed at a time.
I/O expansion adaptor in I/O expansion slot 3 and the fabric connector in slot 2 utilize the same connector and
only one of the two can be installed at a time.
8008010f-2101ffff Device [LogicalDeviceElementName] has been added.
Explanation: The physical presence jumper has been installed in the compute node.
May also be shown as 8008010f2101ffff or 0x8008010f2101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0536
SNMP Trap ID:
8008001b-1f08ffff 8008010f-2101ffff
128
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide