2. Check the Support Portal for firmware updates related to your drive.
3. Replace the drive.
4. Check for any other RAID-related errors.
806f010d-0402ffff The Drive Drive 2 has been disabled due to a detected fault.
Explanation: The hard disk drive controller has detected a fault in hard disk drive 2. Hard disk drive 2 is now
defunct.
May also be shown as 806f010d0402ffff or 0x806f010d0402ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response: Complete the following steps until the problem is solved:
1. Check the Support Portal for service bulletins and RETAIN tips related to your drive.
2. Check the Support Portal for firmware updates related to your drive.
3. Replace the drive.
4. Check for any other RAID related errors.
806f010d-0403ffff The Drive Drive 3 has been disabled due to a detected fault.
Explanation: The hard disk drive controller has detected a fault in hard disk drive 3. Hard disk drive 3 is now
defunct.
May also be shown as 806f010d0403ffff or 0x806f010d0403ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response: Complete the following steps until the problem is solved:
1. Check the Support Portal for service bulletins and RETAIN tips related to your drive.
2. Check the Support Portal for firmware updates related to your drive.
3. Replace the drive.
4. Check for any other RAID-related errors.
806f010d-0404ffff The Drive Drive 4 has been disabled due to a detected fault.
Explanation: The hard disk drive controller has detected a fault in hard disk drive 4. Hard disk drive 4 is now
defunct.
May also be shown as 806f010d0404ffff or 0x806f010d0404ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
806f010d-0402ffff 806f010d-0404ffff
160
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide

Table of Contents