I.580A6 [I.580A6] Memory spare copy has completed successfully.
Explanation: Spare Copy Complete
Severity: Info
User response: Complete the following step:
Check system log for related DIMM failures and replace those DIMMs.
S.1100C [S.1100C] An uncorrectable error has been detected on processor %.
Explanation: Uncorrectable processor error detected
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2. Reboot system. If problem persists escalate to the next level of supprt.
S.2011001 [S.2011001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %. The Vendor ID
for the device is % and the Device ID is %.
Explanation: PCI SERR Detected
Severity: Error
User response: Complete the following steps:
1. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a. Reseat Adapter
and any attached cables. b. Reload Device Driver c. If device is not recognized, reconfiguring slot to Gen1 or
Gen2 may be required. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and I/O
Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
2. Check IBM support site for an applicable device driver, firmware update, service information for this product
revision, or other information that applies to this error. Load new device driver and any required firmware
updates.
3. If problem persists, then remove Adapter Card. If system reboots successfully without the adapter, replace that
card.
4. (Trained Service technician only) Replace the processor.
S.2018001 [S.2018001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %. The Vendor ID
for the device is % and the Device ID is %.
Explanation: PCIe Uncorrected Error Detected
Severity: Error
User response: Complete the following steps:
1. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a. Reseat Adapter
and any attached cables. b. Reload Device Driver c. If device is not recognized, reconfiguring slot to Gen1 or
Gen2 may be required. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and I/O
Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
2. Check IBM support site for an applicable device driver, firmware update, service information for this product
revision, or other information that applies to this error. Load new device driver and any required firmware
updates.
3. If problem persists, then remove Adapter Card. If system reboots successfully without the adapter, replace that
card.
4. Trained Service technician only) Replace the processor.
I.580A6 • S.2018001
Chapter 6. Troubleshooting 447

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System x440 Compute Node and is the answer not in the manual?

IBM Flex System x440 Compute Node Specifications

General IconGeneral
BrandIBM
ModelFlex System x440 Compute Node
CategoryServer
LanguageEnglish

Related product manuals