Severity: Info
Alert Category: System - Event Log Fullness
Serviceable: No
CIM Information: Prefix: IMM and ID: 0037
SNMP Trap ID: 35
Automatically notify Support: No
User response: Information only; no action is required.
40000026-00000000 The [arg1] on system [arg2] is 100% full.
Explanation: The IMM event log is full. New entries in the log will overwrite the oldest entries. To avoid losing
older log entries, save the log as a text file and clear the log.
May also be shown as 4000002600000000 or 0x4000002600000000
Severity: Info
Alert Category: System - Event Log Fullness
Serviceable: No
CIM Information: Prefix: IMM and ID: 0038
SNMP Trap ID: 35
Automatically notify Support: No
User response: To avoid losing older log entries, save the log as a text file and clear the log.
40000027-00000000 Platform Watchdog Timer expired for [arg1].
Explanation: A “Platform Watchdog Timer Expired” event has occurred.
May also be shown as 4000002700000000 or 0x4000002700000000
Severity: Error
Alert Category: System - OS Timeout
Serviceable: No
CIM Information: Prefix: IMM and ID: 0039
SNMP Trap ID: 21
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet-over-USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
5. Check the integrity of the installed operating system.
40000028-00000000 Management Controller Test Alert Generated by [arg1].
Explanation: The Integrated Management Module has sent a test message to help verify connectivity.
May also be shown as 4000002800000000 or 0x4000002800000000
Severity: Info
Alert Category: System - other
Serviceable: No
40000026-00000000 • 40000028-00000000
80
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide