To  perform  some  tasks,  you  can  run  ServeRAID  Manager  as  an  installed  program. 
However,  to  configure  the  integrated  RAID  controller  or  the  installed  ServeRAID 
controller  and  perform  an  initial  RAID  configuration  on  the  server,  you  must  run 
ServeRAID  Manager  in  Startable  CD  mode,  as  described  in  the  instructions  in  this 
section.  If  you  install  a  different  type  of  RAID  adapter  in  the  server,  use  the  method 
that  is  described  in  the  instructions  that  come  with  the  adapter  to  view  or  change 
settings  for  attached  devices. 
See  the  ServeRAID  documentation  on  the  IBM  ServeRAID  Support  CD  for 
additional  information  about  RAID  technology  and  instructions  for  using  ServeRAID 
Manager  to  configure  the  RAID  controller.  Additional  information  about  ServeRAID 
Manager  is  also  available  from  the  Help  menu.  For  information  about  a  specific 
object  in  the  ServeRAID  Manager  tree,  select  the  object  and  click  Actions  →  Hints 
and  tips. 
Configuring  the  controller 
By  running  ServeRAID  Manager  in  Startable  CD  mode,  you  can  configure  the 
controller  before  you  install  the  operating  system.  The  information  in  this  section 
assumes  that  you  are  running  ServeRAID  Manager  in  Startable  CD  mode. 
To  run  ServeRAID  Manager  in  Startable  CD  mode,  turn  on  the  server;  then,  insert 
the  IBM  ServeRAID  Support  CD  into  the  CD  or  DVD  drive.  If  ServeRAID  Manager 
detects  an  unconfigured  controller  and  ready  drives,  the  Configuration  wizard  starts. 
In  the  Configuration  wizard,  you  can  select  express  configuration  or  custom 
configuration.  Express  configuration  automatically  configures  the  controller  by 
grouping  the  first  two  physical  drives  in  the  ServeRAID  Manager  tree  into  an  array 
and  creating  a  RAID  level-1  logical  drive.  If  you  select  custom  configuration,  you 
can  select  the  two  physical  drives  that  you  want  to  group  into  an  array  and  create  a 
hot-spare  drive. 
Using  express  configuration:  To  use  express  configuration,  complete  the 
following  steps: 
1.  In  the  ServeRAID  Manager  tree,  click  the  controller. 
2.  From  the  toolbar,  click  Create. 
3.  Click  Express  configuration. 
4.  Click  Next. 
5.  In  the  “Configuration  summary”  window,  review  the  information.  To  change  the 
configuration,  click  Modify  arrays  or  Modify  logical  drives. 
Note:  Some  operating  systems  have  size  limitations  for  logical  drives.  Before 
you  save  the  configuration,  make  sure  that  the  size  of  the  logical  drive  is 
appropriate  for  your  operating  system. 
6.  Click  Apply;  when  you  are  asked  whether  you  want  to  apply  the  new 
configuration,  click  Yes.  The  configuration  is  saved  in  the  controller  and  in  the 
physical  drives. 
7.  Exit  from  ServeRAID  Manager  and  remove  the  CD  from  the  CD  or  DVD  drive. 
8.  Restart  the  server.
Using
  custom  configuration:  To  use  custom  configuration,  complete  the 
following  steps: 
 
1.  In  the  ServeRAID  Manager  tree,  click  the  controller. 
 
2.  Click  Custom  configuration. 
 
Chapter  4.  Configuring  the  server  51