v  Follow  the  suggested  actions  in  the  order  in  which  they  are  listed  in  the  Action  column  until  the  problem 
is  solved. 
v  See  the  parts  listing  in  the  Problem  Determination  and  Service  Guide  to  determine  which  components  are 
customer  replaceable  units  (CRU)  and  which  components  are  field  replaceable  units  (FRU). 
v  If  an  action  step  is  preceded  by  “(Trained  service  technician  only),”  that  step  must  be  performed  only  by  a 
trained  service  technician. 
Symptom  Action 
A  hard  disk  drive  was  not 
detected  while  the  operating 
system  was  being  started. 
Reseat  all  hard  disk  drives  and  cables;  then,  run  the  hard  disk  drive  diagnostic 
tests  again. 
A  hard  disk  drive  passes  the 
diagnostic  Fixed  Disk  Test  but 
the  problem  remains. 
Run  the  diagnostic  SCSI  Attached  Disk  Test  (see  “Running  the  diagnostic 
programs”  in  the  Problem  Determination  and  Service  Guide  on  the  IBM  System 
x3400  Documentation  CD). 
Note:  This  test  is  available  on  servers  that  have  RAID  arrays  that  uses  the 
onboard  SAS/SATA  controller  or  servers  that  have  SATA  hard  disk  drives  that  are 
connected  to  the  onbaord  SAS/SATA  controller.
 
Intermittent  problems 
 
v  Follow  the  suggested  actions  in  the  order  in  which  they  are  listed  in  the  Action  column  until  the  problem 
is  solved. 
v  See  the  parts  listing  in  the  Problem  Determination  and  Service  Guide  to  determine  which  components  are 
customer  replaceable  units  (CRU)  and  which  components  are  field  replaceable  units  (FRU). 
v  If  an  action  step  is  preceded  by  “(Trained  service  technician  only),”  that  step  must  be  performed  only  by  a 
trained  service  technician. 
Symptom  Action 
A  problem  occurs  only 
occasionally  and  is  difficult  to 
diagnose. 
1.  Make  sure  that: 
v  All  cables  and  cords  are  connected  securely  to  the  rear  of  the  server  and 
attached  devices. 
v  When  the  server  is  turned  on,  air  is  flowing  from  the  fan  grille.  If  there  is  no 
airflow,  the  fan  is  not  working.  This  can  cause  the  server  to  overheat  and 
shut  down.
2.
  Check  the  system/event  error  log  (see  “Error  logs”  in  the  Problem 
Determination  and  Service  Guide  on  the  IBM  System  x3400  Documentation 
CD).
 
 
82  System  x3400  Types  7973,  7974,  7975,  and  7976:  Installation  Guide