EasyManuals Logo
Home>IBM>Server>System x3400 Type 7975

IBM System x3400 Type 7975 User Manual

IBM System x3400 Type 7975
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
A hard disk drive was not
detected while the operating
system was being started.
Reseat all hard disk drives and cables; then, run the hard disk drive diagnostic
tests again.
A hard disk drive passes the
diagnostic Fixed Disk Test but
the problem remains.
Run the diagnostic SCSI Attached Disk Test (see “Running the diagnostic
programs” in the Problem Determination and Service Guide on the IBM System
x3400 Documentation CD).
Note: This test is available on servers that have RAID arrays that uses the
onboard SAS/SATA controller or servers that have SATA hard disk drives that are
connected to the onbaord SAS/SATA controller.
Intermittent problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
A problem occurs only
occasionally and is difficult to
diagnose.
1. Make sure that:
v All cables and cords are connected securely to the rear of the server and
attached devices.
v When the server is turned on, air is flowing from the fan grille. If there is no
airflow, the fan is not working. This can cause the server to overheat and
shut down.
2.
Check the system/event error log (see “Error logs” in the Problem
Determination and Service Guide on the IBM System x3400 Documentation
CD).
82 System x3400 Types 7973, 7974, 7975, and 7976: Installation Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3400 Type 7975 and is the answer not in the manual?

IBM System x3400 Type 7975 Specifications

General IconGeneral
BrandIBM
ModelSystem x3400 Type 7975
CategoryServer
LanguageEnglish

Related product manuals