Table 7. Abbreviated list of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
162 Invalid configuration information or CMOS
random-access memory (RAM) checksum
failure.
1. Run the Configuration/Setup Utility
program, select Load Default Settings,
and save the settings.
2. Reseat the following components:
a. Battery
b. Failing device (If the device is a
FRU, it must be reseated by a
trained service technician only.)
3.
Replace the following components one at
a time, in the order shown, restarting the
server each time:
a. Battery
b. Failing device (If the device is a
FRU, it must be replaced by a
trained service technician only.)
c. (Trained service technician only)
System board
163 The time of day has not set.
1. Run the Configuration/Setup Utility
program, select Load Default Settings,
make sure that the date and time are
correct, and save the settings.
2. Reseat the battery.
3. Replace the following components one at
a time, in the order shown, restarting the
server each time:
a. Battery
b. (Trained service technician only)
System board
175 Service processor flash code damaged or
not loaded.
Note: In this case, the service processor is
the optional Remote Supervisor Adapter II
SlimLine.
1. Update the Remote Supervisor Adapter II
SlimLine firmware (see the Problem
Determination and Service Guide on the
IBM System x3400 Documentation CD).
2. Replace the Remote Supervisor Adapter
II SlimLine.
3. (Trained service technician only) Replace
the system board.
Chapter 5. Solving problems 69

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3400 Type 7975 and is the answer not in the manual?

IBM System x3400 Type 7975 Specifications

General IconGeneral
Processor Sockets2
Memory Slots8 DIMM slots
ChipsetIntel 5000P
NetworkDual Gigabit Ethernet
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
ProcessorIntel Xeon 5000/5100/5300 series, Intel Core 2 Duo
MemoryUp to 32 GB DDR2 ECC
Form FactorTower
RAID SupportRAID 0, 1
Power Supply835W (optional redundant)
Hard Drive InterfaceSATA/SAS

Related product manuals