Table  7.  Abbreviated  list  of  POST  error  codes  (continued) 
v  Follow  the  suggested  actions  in  the  order  in  which  they  are  listed  in  the  Action  column  until  the  problem 
is  solved. 
v  See  the  parts  listing  in  the  Problem  Determination  and  Service  Guide  to  determine  which  components  are 
customer  replaceable  units  (CRU)  and  which  components  are  field  replaceable  units  (FRU). 
v  If  an  action  step  is  preceded  by  ā(Trained  service  technician  only),ā  that  step  must  be  performed  only  by  a 
trained  service  technician. 
Error  code  Description  Action 
1604  Machine  Type  mismatch  detected. 
1.  Update  the  BIOS  code  and  make  sure 
that  the  correct  machine  type  information 
for  the  server  is  correct. 
2.  Update  the  BMC  firmware. 
3.  (Trained  service  technician  only)  Replace 
the  system  board. 
1762  Fixed  disk  configuration  error. 
1.  Run  the  Configuration/Setup  Utility 
program  and  load  the  default  settings. 
2.  Reseat  the  following  components: 
a.  SATA  or  SAS  cable 
b.  Reseat  the  hard  disk  drive 
c.  (Trained  service  technician  only) 
Reseat  the  system  board. 
d.  Replace  the  components  listed  in 
step  2  one  at  a  time,  in  the  order 
shown,  restarting  the  server  each 
time. 
 
72  System  x3400  Types  7973,  7974,  7975,  and  7976:  Installation  Guide