12
SimpleComfort
®
2201 Electronic Thermostat Conversion to:
Comfortmaker CYC Series Heat Pump Systems
SimpleComfort
®
2201
CW2EGBOY1R
Comfortmaker CYC
Low Voltage Terminal Board
R
Y
O
G
W1
W2
X
C
24 VAC, Return
Compressor Contactor
Reversing Valve (Cooling Mode)
Fan Contactor Circuit
2nd Stage Heating Circuit
Outdoor Thermostat
Defrost Sensor
24 VAC, Common
Note 1: E and W2 terminals jumpered at thermostat.
Note 2: W2 terminal on Comfortmaker capped at PCB.
Note 2: X terminal on Comfortmaker capped at PCB.
(capped)