14
SimpleComfort
®
2201 Electronic Thermostat Conversion to:
Payne Reliant and Endura Model Heat Pump Systems
SimpleComfort
®
2201
CW2EGBOY1R
Payne Reliant and Endura Model
Low Voltage Terminal Board
R
Y
O
G
E
W2
L
C
W3
24 VAC, Return
Compressor Contactor
Reversing Valve (Cooling Mode)
Fan Contactor Circuit
Emergency Heating Circuit
2nd Stage Heating Circuit
24 VAC, Common
3rd Stage Heating Circuit
Note 1: W3 terminal on Payne PCB capped at PCB.