EasyManua.ls Logo

ICM Controls SC2201 - Heil-Quaker 867;PH50 Series Wiring

ICM Controls SC2201
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
SimpleComfort
®
2201 Electronic Thermostat Conversion to:
Heil-Quaker 867.814 Series and PH50 Series Heat Pump Systems
SimpleComfort
®
2201
CW2EGBOY1R
Heil-Quaker 867.814 Series and PH50
Low Voltage Terminal Board
R
Y
O
G
W1
W2
C
24 VAC, Return
Compressor Contactor
Reversing Valve (Cooling Mode)
Fan Contactor Circuit
2nd Stage Heating Circuit (Sequencer 1)
3rd Stage Heating Circuit (Sequencer 2)
24 VAC, Common
Note 1: E and W2 terminals jumpered at thermostat.
Note 2: W2 terminal on Heil-Quaker capped at PCB.