15
SimpleComfort
®
2201 Electronic Thermostat Conversion to:
Rheem/Ruud: -PGB, -PFA, -PCB, -PLA, and -PKA Series Heat Pump Systems
SimpleComfort
®
2201
C
W2EGBOY1R
Rheem/Ruud: -PGB, -PFA, -PCB, -PLA, and -PKA
Low Voltage Terminal Board
R
Y
B
G
W2
L
X
O
24 VAC, Return
Compressor Contactor
Reversing Valve (Heating Mode)
Fan Contactor Circuit
2nd Stage Heating Circuit
24 VAC, Common
Note 1: E and W2 terminals jumpered at thermostat.