CONNECTIONS
6
Connections
Transceivers rear panel view
Remote alarm output
IEC61162-1 IN (+)
IEC61162-1 IN (–)
GND
Remote alarm input/CLONE
IEC61162-1 OUT (+)
IEC61162-1 OUT (–)
q NMEA 0183 CONNECTORS
Connects to IEC61162-1 Out lines of a PC or
IEC61162-1 sentence format DSC, DSE compatible
navigation equipment, to receive position data from
other ships.
Connects to IEC61162-1 In lines of a GPS receiver for
position data.
A IEC61162-1 RMC, GGA, GNS, GLL and VTG sentence
format compatible GPS receiver is required. Ask your
dealer about suitable GPS receivers.
t
y
e
w
r
q
Remote alarm output terminal
• 4 V DC*
• Maximum 10 mA*
* When the external equipment is connected between this terminal
and the GND terminal.
When DSC call that is related to “Distress” as described
below is received, 4 V DC is output and the key backlight
blinks.
• Distress call
• Distress acknowledgement
• Distress Relay call
• Distress Relay acknowledgement
• Distress Cancel call
• DSC call whose category is “Distress”
Remote alarm input terminal
When this terminal shorts to the GND terminal, the
transceiver sends the Distress call.
This terminal can be used as an external distress switch.