■ Power supply connections
D Connecting to the DC power supply through the PS-310
CAUTION:
Before connecting the DC power cable, conrm the
transceiver is OFF, and the DC power cable polarity is
correct.
• Red: Positive + terminal
• Black: Negative − terminal
BE SURE to connect only the DC power cable from the
PS-310, and DO NOT extend the cable length.
PS-310
GM600
Battery
(12 V or 24 V, depending on the PS-310 version.)
DC power cable
( Supplied with the PS-310)
DC power cable
GND
You must connect the GM600 to the DC power source
through the PS-310
dc-dc power supply, sold by the set
with the GM600, when you operate the GM600.
The PS-310 converts the input voltage from the DC power
supply, then provides 12.6 V DC, 5.5 A of the continuous
power to the transceiver.
Select the appropriate version for your vessel power system.
• PS-310
Version Input voltage Output voltage
#01 21.6 ~ 31.2 V DC 12.6 V DC
#02 10.8 ~ 15.6 V DC 12.6 V DC