17
3 BASIC OPERATION
New2001
Squelch attenuator
The transceiver has an RF attenuator related to the squelch
level setting. Approx. 10 dB attenuation is obtained at maxi-
mum setting.
The squelch attenuator allows you to set a minimum signal
level needed to open the squelch. The attenuator function can
be deactivated in initial set mode.
Rotate [SQL] clockwise past the 12 oclock position to ac-
tivate the squelch attenuator.
Attenuation level can be adjusted up to 10 dB (approx.) between
12 oclock and fully clockwise position.
When setting the squelch from the microphone, a level greater
than 19 activates the squelch attenuator.
NOTE: The squelch attenuator functions even when the
monitor function is in use. Thus set the [SQL] control within
10 to 12 oclock position is recommended when using the
monitor function.
D Squelch attenuator setting
qTurn the transceiver power OFF.
wWhile pushing
[SET ],
turn the power ON to enter initial
set mode.
ePush
[SET ] or [LOWPRIO] to select Att-On (squelch
attenuator) item.
rRotate the left bands [DIAL] to toggle the function ON and
OFF.
Select OF to deactivate the squelch attenuator function.
t Push [PWR] to exit initial set mode.
USING
INITIAL SET MODE
IC-2720H_2.qxd 03.5.13 9:45 Page 17 (1,1)