EasyManua.ls Logo

Icom IC-756PRO2 - I Select Memory Scan Operation; I Setting Select Memory Channels

Icom IC-756PRO2
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
7
SCANS
Select memory scan operation
q Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w Select memory mode.
e Push [(F-5)SCAN] to select the scan screen.
r Set [RF/SQL] open or closed.
See p. 57 for scan condition.
If the [RF/SQL] control function is set as AUTO, the
squelch is always open in SSB, CW and RTTY modes.
See pgs. 3, 69 for details.
t Push [(F-1)MEMO] to start the memory scan.
Decimal points blink while scanning.
y Push [(F-3)SELECT] to start select memory scan;
push [(F-3)SELECT] again to return to memory
scan, if desired.
u When the scan detects a signal, the scan stops,
pauses or ignores it depending on the resume set-
ting and the squelch condition.
i To cancel the scan, push [(F-1)MEMO].
2 or more memory channels must be designated
as select memory channels for select memory
scan to start.
SFTSFT
0
FIL2FIL2
USBUSB
qw:pp
TXTX
VFOVFO
USBUSB
USBUSB
USBUSB
FIL2FIL2
qr.qot.pp
qr.wpt.pp
14.100.0014.100.00
14.100.0014.100.00
1
VFOVFO
BWBW
2.4k2.4k
SCANSCAN
1212ß
ANTANT
1
COMPCOMP
OFFOFF
WIDEWIDE
METERMETER
PoPo
P.AMPP.AMP
1
AGCAGC
MIDMID
ATTATT
OFFOFF
VOXVOX
OFFOFF
MEMOMEMO
F SELECTSELECT
F SPANF SPAN
SETSET
SELECT MEMORY SCANSELECT MEMORY SCAN
F SpanSpan: ±±10kHz10kHz
ProgrammedProgrammed P1:P1:0.500.00MHz0.500.00MHz
scanscan edgesedges P2:P2: 29.999.99MHz29.999.99MHz
SFTSFT
0
FIL2FIL2
USBUSB
qw:pp
TXTX
VFOVFO
USBUSB
USBUSB
USBUSB
FIL2FIL2
qr.qot.pp
qr.wpt.pp
14.100.0014.100.00
14.100.0014.100.00
1
VFOVFO
12 12
BWBW
2.4k2.4k
SCANSCAN
ANTANT
1
COMPCOMP
OFFOFF
WIDEWIDE
METERMETER
PoPo
P.AMPP.AMP
1
AGCAGC
MIDMID
ATTATT
OFFOFF
VOXVOX
OFFOFF
MEMOMEMO
F SELECTSELECT
F SPANF SPAN
SETSET
F SpanSpan: ±±10kHz10kHz
ProgrammedProgrammed P1:P1:0.500.00MHz0.500.00MHz
scanscan edgesedges P2:P2: 29.999.99MHz29.999.99MHz
Setting select memory channels
q Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w Select memory mode.
e Push [(F-5)SCAN] to select the scan screen.
r Select the desired memory channel to set as a se-
lect memory channel.
t Push [(F-3)SELECT] to set the memory channel
as a select memory or not.
y Repeat steps r to t to program another memory
channel as a select memory channel, if desired.
u Push [EXIT/SET] to exit the scan screen.
Select memory channels can also be set in the
memory channel screen. (p. 52)
1212ß
SFTSFT
0
FIL2FIL2
USBUSB
qw:pp
TXTX
VFOVFO
USBUSB
USBUSB
USBUSB
FIL2FIL2
qr.qot.pp
qr.wpt.pp
14.100.0014.100.00
14.100.0014.100.00
1
VFOVFO
BWBW
2.4k2.4k
SCANSCAN
ANTANT
1
COMPCOMP
OFFOFF
WIDEWIDE
METERMETER
PoPo
P.AMPP.AMP
1
AGCAGC
MIDMID
ATTATT
OFFOFF
VOXVOX
OFFOFF
MEMOMEMO
F SELECTSELECT
F SPANF SPAN
SETSET
ß appears for select memory channels.
F SpanSpan: ±±10kHz10kHz
ProgrammedProgrammed P1:P1:0.500.00MHz0.500.00MHz
scanscan edgesedges P2:P2: 29.999.99MHz29.999.99MHz
SFTSFT
0
FIL2FIL2
USBUSB
qw:pp
TXTX
VFOVFO
USBUSB
USBUSB
USBUSB
FIL2FIL2
qr.qot.pp
qr.wpt.pp
14.100.0014.100.00
14.100.0014.100.00
1
VFOVFO
12 12
BWBW
2.4k2.4k
SCANSCAN
ANTANT
1
COMPCOMP
OFFOFF
WIDEWIDE
METERMETER
PoPo
P.AMPP.AMP
1
AGCAGC
MIDMID
ATTATT
OFFOFF
VOXVOX
OFFOFF
MEMOMEMO
F SELECTSELECT
F SPANF SPAN
SETSET
F SpanSpan: ±±10kHz10kHz
ProgrammedProgrammed P1:P1:0.500.00MHz0.500.00MHz
scanscan edgesedges P2:P2: 29.999.99MHz29.999.99MHz

Table of Contents