43
DSC OPERATION
7
New2001
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Data Output (Default:Off)
When receiving a DSC call from the station that is selected
in this setting, the transceiver outputs the DSC data to the
NMEA output port.
L You can send Distress calls despite of this setting.
AllStations: Fromanystation.
StationsList: FromthestationsthatareenteredIndividual
IDorGroupIDontheMenuscreen.
OFF: DoesnotoutputanyDSCdatafromthe
NMEA 0183 Output port.
Alarm Status
Set the alarm ON or OFF for each DSC related item.
• Safety (Default:On)
AnalarmsoundswhenaSafetyDSCcallisreceived.
• Routine (Default:On)
AnalarmsoundswhenaRoutineDSCcallisreceived.
• Warning (Default:On)
Analarmsoundswhen:
-NoMMSIcodeisentered.
-Thepositiondatahasnotbeenreceivedfor2minutes
after turning ON the transceiver.
-Thereceivedpositiondatahasnotbeenupdatedfor10
minutes.
-Thereceivedpositiondatahasnotbeenupdatedfor4
hours.
-Themanuallyenteredpositiondatahasnotbeenupdated
for 23.5 hours.
• Self-Terminate (Default:On)
AnalarmsoundswhenduplicateDSCcallsarereceived.
• Self-Terminate (Default:On)
AnalarmsoundswhenduplicateDistresscallsare
received.
• Discrete (Default:On)
Analarmsoundswhenalowerprioritycallisreceived
whilereceivingahighprioritycall.
CH 70 SQL Level (Default:3)
AdjusttheSquelchlevelforChannel70tobetween1and
10, or Open.