I Single Package Heat Pumps
Thermostat Fan Switch Operation
With the thermostat fan switch in the ON position, the circu-
lating air blower will run continuously.
With the thermostat fan switch in the AUTO position, the
circulating air blower will only run during a cooling or heat-
ing cycle and when the electric heat accessory is required if
the electric heat accessory is installed.
Adjusting RoomTemperatures
Ifthe temperature in individual rooms is not as desired, bal-
ance the system by adjusting the dampers in the branch
ducts. Adjust a little at a time and wait a day after each
change to judge the effect. Once the dampers are adjusted
for normal weather conditions, it is best to leave them that
way. Compensate for temporary weather changes by ad-
justing the thermostat setting.
10.Maintenance
FIGURE 14
Installation Instructions
Typical Branch Duct Dampers
Air Filters, Condenser Coil and Condensate
Drain Maintenance
Refer to Home Owners Manual supplied with your heat
pump for information on filter sizes, condenser coil clear-
ances from shrubbery and condensate drainage allow-
ances.
CAUTION
Do NOT operate unit without filters in place. Inspect
filters monthly and clean and/or replace as needed.
Refrigeration Access Ports
This unit is equipped with refrigeration access ports
mounted on the side of the unit. Refer to FIGURE 15 for
identification of ports.
This unit is also equipped with internal access ports on the
suction and discharge tubing line which can be used for
evacuation, pull down and recharging of the refrigeration
system.
FIGURE 15 Typical Access Po_s