ICT Protege - Reread Mode Settings; Reader Address Configuration; UART Configuration

Default Icon
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reread Mode
Configure the reader to continuously reread a card that is kept within range.
This option can be used with the tSec Extra Card Holder Cover (Ordering code: PRX-TSEC-XCDH) .
The reader will send a card read to the controller every 3 seconds while a card is present in front of the reader,
regardless of whether the card has been read before. The reader can also be set to silently reread the card, where
it disables the beeps generated when the card is read.
Reread Mode:
- Enable Reread
- Silent Reread
There is currently no selection option to disable this programming once enabled. To disable reread mode, apply a
Hex TLVwith hex code 200100.
Reader Address
This TLVis only valid for protocols which support addressing (ICT RS485, OSDP or Smart Serial).
The Reader Address TLV allows you to program the reader's address configuration.
This may be required to set a specific address when connecting to third-party systems.
This TLVcan also be used to configure an RS-485 reader as an entry reader (address 0) or exit reader (address 1).
This does not apply for tSec readers with the green and orange wires joined. When these wires are joined the
reader is always an exit reader and the address cannot be configured.
Reader Address: Enter the address to program the reader with. The maximum supported address is 127.
Uart Configuration
Define the baud rate of the RS-485 interface for compatibility with third-party systems.
Baud:
- 4800
- 9600
- 14400
- 19200
- 38400
- 57600
- 115200