67
o Output Status. In this submenu you can view witch output relays are
latched, or unlatched.
Output state entrapment (K1) “relay not energized / relay
energized”
Output state prewarn (K2) “relay not energized / relay energized”
Output state auxiliary #1 (K3) “relay not energized / relay
energized”
Output state auxiliary #2 (K4) “relay not energized / relay
energized”
Output state auxiliary #3 (K5) “relay not energized / relay
energized”
o Motor Current. (for model DCM only) This submenu is used only for to
view amp draw of the motor so the proper value can be inserted in the
safety threshold submenu.
Leaf # 1 maximum deviation threshold, last cycle (gate stopped)
X.X A (gate stopped)
Motor Current Leaf #1 (gate moving)
Approx Motor Current (gate moving)
X.X A (this value changes as the gate moves thru a cycle. Watch
for the highest value during the cycle to enter a proper setting in
the safety threshold submenu leaf #1)
Leaf # 2 maximum deviation threshold, last cycle (gate stopped)
X.X A (gate stopped)
Motor Current Leaf #1 (gate moving)
Approx Motor Current (gate moving)
X.X A (this value changes as the gate moves thru a cycle. Watch
for the highest value during the cycle to enter a proper setting in
the safety threshold submenu leaf #2)
o Battery Voltage. (for model DCM only) This submenu shows voltage
being supplied to the logic board. Any voltage over 24 vdc will show as
24 volts.
Leaf #1 / 24.0 volts
Leaf # 2 / 24.0 volts
TIMING AND OPTIONS. In this menu you can adjust user settings.
o Basic settings
Current clock time (factory set to mountain time) “12:01 am”
Current calendar date “1/1/2013”
Auto-Close delay (factory set at 10 seconds) “OFF / 15:00”
Close command over rides auto-close (factory set Enabled)
“Disabled / Enabled”
Single input sets the auto-close timer (factory set Enabled)
“Disabled / Enabled”
Single input direction reverse (factory set Enabled) “Disabled /
Enabled”