68
Pause delay before direction reversal (factory set Enabled)
“Disabled / Enabled”
o Safety Responses
Maximum motor run (0:30 seconds factory set) “0:05 to 1:30”
Motion reversal on safety (factory set Enabled) “Disabled /
Enabled”
Safety sets the auto-close timer (factory set Enabled) “Disabled /
Enabled”
Inherent safety (for model DCM only factory set Disabled)
“Disabled / Enabled”
Safety threshold Leaf # 1 closing (for model DCM only value set
at factory, Inherent safety must be checked monthly) “0.0 A to
20.0 A”
Safety threshold Leaf # 1 opening (for model DCM only value set
at factory, Inherent safety must be checked monthly) “0.0 A to
20.0 A”
Safety threshold Leaf #2 closing (for model DCM only value set at
factory, Inherent safety must be checked monthly) “0.0 A to 20.0
A”
Safety threshold Leaf #2 opening (for model DCM only value set
at factory, Inherent safety must be checked monthly) “0.0 A to
20.0 A”
Motor inrush ignore period (factory set 1.0 seconds) “0.0 seconds
to 2.0 seconds”
Position Feedback Obstruction Detect (for hydraulic gate only)
(factory set Enabled) “Disabled / Enabled”
Monitored Obstruction Edge “Disabled / Enabled”
o Speed Settings (for model DCM only)
Gate position for ramp up completion (factory set 5%) “XX%”
Gate position for ramp down start (factory set 80%) “XX%”
Slow stop ramp-down on gate reversal (factory set 0.5 seconds)
“0.0 seconds to 3.0 seconds”
Motor ramp starting speed (factory set 60%) “XX%”
Maximum motor speed (factory set 100%) “XX%”
Motor ramp end speed (factory set 40%) “XX%”
o Lockout Schedule. When lockout schedule is set the gate will not open
until lockout schedule ends except for a free exit loop will open the gate,
or an input to terminal timer set input I7.
Entry lockout enable Schedule # 1 “Disabled / Enabled”
Entry lockout start Schedule # 1 “ set for time to start lockout am
or pm and day of week”
Entry lockout end Schedule # 1 “set for time to end lockout am or
pm and day of week”
Repeat for all days that Lockout is needed.