69
o Auto-Open schedule. When auto-open schedule is set no function will
close gate until auto-open schedule ends.
Auto-Open gate enable Schedule # 1 “Disabled / Enabled”
Auto-Open gate start time Schedule # 1 “set for time to start auto-
open am or pm and day of week”
Auto-Open gate end time Schedule # 1 “set for time to end auto-
open am or pm and day of week”
Repeat for all days that Auto-Open is needed.
o Battery (for model DCM only)
Fail-Safe / Fail-secure Selection “fail safe / fail secure”
Battery dropout voltage (factory set 18.0 volts) “17.0 to 23.0”
Battery recovery voltage (factory set 20.0 volts) “18.0 to 23.0”
o Auxiliary I / O
Auxiliary #1 input function assignment “not used / open / close/
stop / single / timer hold / reverse open loop / opening safety edge /
closing safety edge / UL entrapment reset”
Auxiliary #2 input function assignment “not used / open / close/
stop / single / timer hold / reverse open loop / opening safety edge /
closing safety edge / UL entrapment reset”
Auxiliary output #1 function “output disabled / secondary
entrapment alarm / hold aux relay when maintenance due / hold
aux relay on auto-close delay / unlock pulse / pulse aux relay on
close limit switch / pulse aux relay on open limit switch / pulse aux
relay on open motion / pulse aux relay on close motion / hold aux
relay on close limit switch / hold aux relay on open limit switch /
hold aux relay on opening motion / hold aux relay on closing
motion / pulse aux relay on motion prewarn / pulse aux relay on
opening prewarn only / pulse aux relay on closing prewarn only /
pulse aux relay on auxiliary input #1 / hold aux relay on auxiliary
input #1 / pulse aux relay on auxiliary input #2 / hold aux relay on
auxiliary input #2 / hold aux relay on any motion / hold aux relay
on arming loop assertion”
Auxiliary output #1 pulse duration “0.1 seconds to 5.0 seconds”
Auxiliary output #2 function “output disabled / secondary
entrapment alarm / hold aux relay when maintenance due / hold
aux relay on auto-close delay / unlock pulse / pulse aux relay on
close limit switch / pulse aux relay on open limit switch / pulse aux
relay on open motion / pulse aux relay on close motion / hold aux
relay on close limit switch / hold aux relay on open limit switch /
hold aux relay on opening motion / hold aux relay on closing
motion / pulse aux relay on motion prewarn / pulse aux relay on
opening prewarn only / pulse aux relay on closing prewarn only /
pulse aux relay on auxiliary input #1 / hold aux relay on auxiliary
input #1 / pulse aux relay on auxiliary input #2 / hold aux relay on