iDM iPUMP A 2-7 - Exchange of the Magnesium Protection Anode

iDM iPUMP A 2-7
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(C) IDM ENERGIESYSTEME GMBH
1
0
. Mag
n
esium protectio
n
a
n
od
e
Installation instructions iPump A 2-7, 3-11
50
magnesium protection anode
Kapitel 10
10.3. Exchange of the magnesium protec-
tion anode
Before the anode is unscrewed, the bu er must be
emptied. The drain valve is located on the underside
of the bu er. For draining a hose must be connected.
In order to protect the underlying electric from any
escaping residual water, it is best to cover it with a
foil.
The black connection line between the anode and the
bu er must be terminated.
Then the anode can be unscrewed by a suitable pipe
wrench.
The used magnesium protective anode can now be
pulled out and replaced by a new one.
The new anode will be screwed rmly and the black
connection cable between the anode and the bu er
must be pluged.
After re lling the bu er, it must be checked for leaks
in the area of the protective anode.