Installation instructions iPump A 2-7, 3-11
58
Technical documentation
Kapitel 13
14. Technical documentation
TECHNICAL DOCUMENTATION
according Directive 2010/30/EU and corresponding Regulation (EU) No. 811/2013 (Energy Labelling),
Dircetive 2009/125/EC and corresponding Regulation (EU) No. 813/2013 (Ecodesign)
Rev.0/01-12-2016
Model:
Type of heat pump:
Low-temperature heat pump: (Yes/No)
Temperature application: (35°C/55°C)
Equipped with supplementary heater: (Yes/No)
Heat pump combination heater: (Yes/No)
Yes
iPump A 2-7
Air-to-water heat pump
Yes
high temperature (55°C)
Yes
Heat pump combination heater: (Yes/No)
cold average warm cold average warm
Rated heat output
P
rated
4,6 4,3 6,5 kW Seasonal space heating efficiency
Ș
s
129 150 192 %
Climate condition Climate condition
Dl d itf tld
Dl d itf tld
Yes
Outdoor temperature T
j
Outdoor temperature Tj
T
j
= – 15 °C P
dh
3,7 - - kW
T
j
= – 15 °C COP
d
2,04 - - ---
T
j
= – 7 °C P
dh
2,8 4,0 - kW
T
j
= – 7 °C COP
d
2,83 2,49 - ---
T
j
= +2 °C P
dh
1,9 2,3 6,5 kW
T
j
= +2 °C COP
d
4,10 3,66 2,31 ---
T
j
= +7 °C P
dh
2,4 2,3 4,2 kW
T
j
= +7 °C COP
d
6,15 2,29 3,98 ---
T
j
= +12 °C P
dh
2,8 2,8 2,7 kW
T
j
= +12 °C COP
d
9,17 2,82 2,72 ---
Declared capacity for part load
(indoor temperature = 20 °C)
Declared capacity for part load
(indoor temperature = 20 °C)
T
j
= Bivalenz temperature (T
biv
) P
dh
3,7 4,5 6,5 kW
T
j
= Bivalenz temperature (T
biv
) COP
d
2,04 2,11 2,31 ---
T
j
= Operation limit temperature (TOL) P
dh
3,4 4,5 6,5 kW
T
j
= Operation limit temperature (TOL) COP
d
1,86 2,11 2,31 ---
Bivalenz temperature (Tbiv)
T
biv
-15,0 -10,0 2,0 °C Operation limit temperature TOL -18,0 -10,0 2,0 °C
Cycling interval capacity for heating
P
cych
kW Cycling interval capacity for heating
COP
cyc
---
Degradation co-efficient
C
dh
0,9 0,9 0,9 --- Heating water operating limit temperature WTOL 62 62 62 °C
Power consumption in modes other than active mode Supplementary heater
Thermostat
-
off mode
P
TO
0025
0 025
0 025
kW
Rated heat output (
*
)
P
sp
1
-
6
1
-
6
1
-
6
kW
Thermostat
-
off mode
P
TO
0
,
025
0
,
025
0
,
025
kW
Rated heat output ( )
P
sup
1
-
6
1
-
6
1
-
6
kW
Standby mode
P
SB
0,022 0,022 0,022 kW
Off-mode
P
OFF
0,022 0,022 0,022 kW Type of energy input
Crankase heater mode
P
CK
000kW
Other items For air-to-water heat pumps:
Capacity control Rated air flow rate, outdoors --- 2.500
m
3
/h
Sound power levels, indoors/outdoors
L
WA
42.3/45.7 42.3/45.7 42.3/45.7 dB
For water- or brine-to-water heat pumps:
electrical
variable
Annual energy consumption
Q
HE
3.407 2.368 1.900 kWh Rated brine or water flow rate, outdoor heat exchanger --- n.a. n.a. n.a.
m
3
/h
For heat pump combination heater:
Declared load profile Water heating energy efficiency
Ș
wh
%
Daily electricity consumption
Q
elec
kWh Daily fuel consumption
Q
fuel
n.a. n.a. n.a. kWh
Annual electricity consumption AEC kWh Annual fuel consumption AFC n.a. n.a. n.a. GJ