4.  Disarming the Control Panel    
4.1  How to Disarm with a User Code    
 
[#] [USER CODE] 
 
1.  Enter the premises through a designated entry route. Entering via any other route will cause an 
alarm. 
2.  As  soon  as  the  Entry/Exit  zone  is  violated,  the  entry  delay  will  begin.  The  keypad  buzzer  will 
sound for the duration of the entry period.  
3.  Press the [#] key and enter a valid [USER CODE]. If an error beep occurs, press the [#] key and 
re-enter the user code. 
4.  Once the system disarms, the ARM LED will turn off and the keypad buzzer will stop sounding. 
5.  If  no  valid  user  code  has  been  entered  prior  to  the  expiry  of  the  entry  delay  period  an  alarm 
condition will be registered. 
6.  If the entry period is too short, have your installer change the entry delay period. 
 
NOTE:    
If  a  strobe  (or  flashing  light)  has  been  installed  and  an  alarm  condition  is  registered,  the  strobe  will 
continue flashing  after the  siren has  stopped  sounding.  Entering  a valid  [USER CODE]  will cancel the 
strobe. 
4.2  How to Disarm using a Key-Switch or Remote              
 
1.  Activate  the  remote  or  key-switch.  (The  blue  button  on  the  remote,  unless  otherwise 
programmed). 
2.  The  system  will  disarm  and  the  remote  indicator  (if  installed)  will  turn  off.  If  the  siren  toot  on 
disarm  option  is  enabled,  the  siren  will  provide  a  double  toot  when  the  panel  is  disarmed.
5.  Bypassing Zones     
 
  The  term  BYPASS  is  used  to  describe  a  zone  that  has  been  deactivated;  i.e.  violation  of  a 
bypassed zone is ignored and will not cause an alarm condition. 
  Once the system is armed, it is not possible to bypass zones. 
  All bypassed zones will be automatically cancelled each time the panel is disarmed and must be 
re-bypassed before the next arming. 
5.1  How to Bypass / Un-bypass a Zone            
 
Hold down [9] until the beep, 
then enter [USER CODE] [*] [ZONE NUMBER] [*] [*] [#] 
 
1.  Ensure the panel is not armed. 
2.  To enter bypass mode, hold down [9] until the beep. 
3.  The LCD display reads „User Code + *‟. 
4.  Enter the [USER CODE] followed by the [*] key.