[0] [*]  Copy All –  this is  used  to update  the zone  names to all  keypads  connected  to the  X-
series Alarm Panel. This is used when a keypad has been replaced or a new keypad is 
added to the panel. (This can be used when you replace a keypad and want it to display 
the existing zone names). 
[111] [*]  Delete  Name  –  this  is  used  to  delete  the  zone  name  being  viewed  from  the  X-series 
Alarm Panel.  
[222] [*]  Delete All – this option is used to delete all zone names from the X-series Alarm Panel. 
8.3.13  Option 40 - Edit the Time           
 
[*] [MASTER CODE] [*] [4] [0] [*] [TIME] [*] [#] 
 
1.  Enter the User Program Mode as per steps 1 - 4 of section 8.2. 
2.  The LCD display reads „Option Menu‟, „Add User Code‟.  
3.  To  select  menu  option  40  –  „Edit  Time‟,  press  the  [4]  [0]  keys  followed  by  the  [*]  key  or 
alternatively use the [PANIC]  or [MED] keys to scroll through the list of programmable options 
until you reach the option you want. 
4.  Press the [*] key. 
5.  The LCD display reads „New Time?‟. 
6.  Enter the [TIME] that you wish to edit, followed by the [*] key. The format is HHMM. 
7.  Press the [#] key to exit the User Program Mode. 
8.3.14  Option 41 - Edit the Date           
 
[*] [MASTER CODE] [*] [4] [1] [*] [DATE] [*] [#] 
 
1.  Enter the User Program Mode as per steps 1 - 4 of section 8.2. 
2.  The LCD display reads „Option Menu‟, „Add User Code‟.  
3.  To  select  menu  option  41  –  „Edit  Date‟,  press  the  [4]  [1]  keys  followed  by  the  [*]  key  or 
alternatively use the [PANIC]  or [MED] keys to scroll through the list of programmable options 
until you reach the option you want. 
4.  Press the [*] key. 
5.  The LCD display reads „New Date?‟ 
6.  Enter the [DATE] that you wish to edit, followed by the [*] key. The format is DDMMYY.  
7.  Press the [#] key to exit the User Program Mode.
9.  Stay Zones     
 
Stay zones are those zones that are bypassed automatically when the system is "STAY ARMED". To avoid 
triggering the alarm, zones such as bedrooms that are protected by Passive Infra-Red (PIR) detectors or 
windows  that  may  be  opened,  must  be  bypassed  when  "staying  at  home".  Stay  zones  need  only  be 
programmed once. Each time the system is armed in the Stay Mode the pre-selected stay zones will be 
bypassed automatically. The panel allows for four unique STAY PROFILES to be stored. A STAY PROFILE 
stores a preselected combination of STAY and BUZZ zones to suit a specific STAY ARM requirement. If a 
partition is stay armed using Profile 1, it  is possible to toggle the panel arm status directly to stay arm 
profile 2 by holding the [5]  key for two seconds. STAY and BUZZ zones can be programmed for each 
profile once the profile has been selected. See sections 9 & 10.