8.2  How to Enter the User Program Mode    
 
1.  Ensure that the panel is not armed. 
2.  Hold down the [*] key until the keypad buzzer sounds.  
3.  The  LCD  display reads  „Master Code  +  *‟.  The  factory  default is  [1234].  Should  the MASTER 
USER CODE be set to six digits it will be [123456] by default. 
4.  Enter the [MASTER USER CODE], followed by the [*] key. A valid entry will be confirmed by a 
long beep. If an invalid MASTER USER CODE was entered, the keypad buzzer will give an error 
beep (3 short beeps). 
5.  The first menu option – „Option Menu‟, „Add User Code‟ is displayed by default. 
6.  Select a programmable option from Table 1. One may use the [PANIC] or [MED] keys to scroll 
through the menu options. 
7.  Confirm the entry by pressing the [*] key. A valid entry is confirmed by a long beep. An invalid 
entry will be signalled by means of an error beep (3 short beeps). If an error beep occurs, press 
the [#] key to clear all previous entries, and repeat steps 2 – 6. 
 
EXAMPLE: 
To add  a new user code, enter  User Program Mode by completing steps 2  - 4  as listed  above. Menu 
Option 0 will be displayed on the LCD screen by default. Press the [*] key to confirm your entry. Once 
prompted  to „Enter  a User Code‟,  input a  [NEW  USER CODE]  followed by  the [*] key.  Once the user 
code is programmed, enter the next code followed by [*]. To exit the program mode press the [#] key. 
For a full list of options, refer to Table 1. Programming of these options is explained below. 
8.3  Explanation of Programmable Options    
8.3.1  Option 0 - Add a New User Code     
 
[*] [MASTER CODE] [*] [0] [*] [NEW CODE] [*] [#] 
 
1.  Enter the User Program Mode as per steps 1 - 4 of section 8.2. 
2.  The LCD display reads „Option Menu‟, „Add User Code‟. As this is the programmable option you 
require, press the [*] key. 
3.  The LCD display reads „New Code + *‟. 
4.  Enter [NEW USER CODE] followed by the [*] key.  
5.  A valid entry is confirmed by a long beep. An invalid entry will be signalled by means of an error 
beep (3 short beeps). If an error beep occurs, press the [#] key to clear all previous entries and 
repeat steps 1-4. 
6.  Further codes can be added by repeating step 4 above. When a user code is added, it is stored 
in the first available user slot. 
7.  Press the [#] key to exit the User Program Mode. 
8.3.2  Option 1 - Edit a Selected User Code     
 
[*] [MASTER CODE] [*] [1] [*] [OLD CODE] [*] [NEW CODE] [*] [#] 
 
1.  Enter the User Program Mode as per steps 1 - 4 of section 8.2. 
2.  The LCD display reads „Option Menu‟, „Add User Code‟.