10.1 How to Program / Cancel Buzz Zones
[4] [ZONE NUMBER] [*] [#]
1. Select the required Stay Profile. (See section 9.1)
2. Hold down the [4] key until the keypad buzzer sounds.
3. The LCD display reads „Zone Number + *‟.
4. Press the [ZONE NUMBER] corresponding to the zone you wish to be programmed as a Buzz
zone followed by the [*] key. Alternatively use the [PANIC] or [MED] keys to scroll through the
zones.
5. A [Y] next to the zone number indicates that the zone has been programmed as a Buzz zone.
Flashing text indicates a Stay zone.
6. Press the [*] key to toggle between YES and NO.
7. Repeat steps 4 - 6 until all the required Buzz zones are programmed/cancelled.
8. Press the [#] key to exit the Buzz zone programming mode.
NOTE:
A zone cannot be both a Buzz and Stay Zone.
A Stay zone cannot be selected as a Buzz zone.
11. Chime Zones
The chime mode allows the user to monitor nominated zones while the system is disarmed. The keypad
buzzer will sound briefly when the nominated zone is violated - the siren will NOT sound and no alarm
condition will be reported.
EXAMPLE:
If you wish to know each time someone enters or exits the front door of your office, program this zone as
a chime zone, the keypad will beep each time someone opens the front door.
11.1 How to Program / Cancel Chime Zones
[2] [ZONE NUMBER] [*] [#]
1. Hold down the [2] key until the keypad buzzer sounds.
2. The LCD display reads „Zone Number + *‟.
3. Press the [ZONE NUMBER] corresponding to the zone you wish to be a Chime zone followed by
the [*] key. Alternatively use the [PANIC] or [MED] keys to scroll through the zones.
4. A [Y] next to the zone number indicates that the zone has been selected as a Chime zone.
5. Press the [*] key to toggle between YES and NO.
6. Repeat steps 3 - 5 until all the required Chime zones are programmed/cancelled.
7. Press the [#] key to exit the Chime zone programming mode.